TMP92CM22

2007-02-16

92CM22-177

Serial Bus Interface Baud Rate Register 0

7 6 5 4 3 2 1 0

Bit symbol

− I2SBI0

SBI0BR0
(1244H)

Read/Write

W

R/W

After

reset

0

0

Function

Always
write “0”.

IDLE2
0: Stop
1: Run

0 Stop

1 Run

Serial Bus Interface Baud Rate Register 1

7 6 5 4 3 2 1 0

Bit symbol

P4EN

SBI0BR1
(1245H)

Read/Write W

After

reset

0

0

Function

Internal
clock
0: Stop
1: Run

Always
write “0”.

0 Stop

1 Run

Sirial Bus Interface Data Buffer Register

7 6 5 4 3 2 1 0

Bit symbol

DB7

DB6

DB5 DB4 DB3 DB2 DB1 DB0

SBI0DBR

(1241H)

Read/Write

R (Receiving)/W (Transmission)

After

reset

Undefined

Read-
modify-write
instruction is
prohibited.

Note 1: When writing transmission data, start from the MSB (Bit7). Receiving data is placed from LSB (Bit0).

Note 2: SBI0DBR can’t be read the written data. Therefore read-modify-write instruction (e.g., “BIT” instruction) is

prohibited.

I

2

C Bus Address Register

7 6 5 4 3 2 1 0

Bit symbol

SA6

SA5

SA4 SA3 SA2 SA1 SA0 ALS

I2C0AR
(1242H)

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Read-
modify-write
instruction is
prohibited.

Function

Slave address selection for when device is operating as slave device

Address
recognition
mode
specification

0

Slave address recognition

1

Non slave address recognition

Figure 3.10.6 Register for I

2

C Bus Mode

Operation during IDLE 2 mode

Operation during IDLE 2 mode

Address recognition mode specification

Read-

modify-write

instruction is

prohibited.

Read-

modify-write

instruction is

prohibited.

Advertising