2 ac characteristics, 1 basis bus cycle, Read cycle – Toshiba H1 SERIES TLCS-900 User Manual

Page 220: No. parameter symbol min max f, 20 mhz (fc = 40 mhz) f, 125 khz (fc = 4 mhz) unit, Write cycle

Advertising
background image

TMP92CM22

2007-02-16

92CM22-218

4.2 AC

Characteristics

4.2.1

Basis Bus Cycle

Read cycle

Vcc

= 3.3 ± 0.3 V/fc = 4 to 40 MHz/Ta = −40 to 85°C

No. Parameter Symbol

Min

Max

f

SYS

=

20 MHz

(fc

= 40 MHz)

f

SYS

=

125 kHz

(fc

= 4 MHz)

Unit

1 OSC period (X1/X2)

t

OSC

25 250

25

250 ns

2 System clock period (

= T) t

CYC

50 8000 50

8000

ns

3 CLKOUT

low

width

t

CL

0.5T

− 15

10

3985

ns

4 CLKOUT

high

width

t

CH

0.5T

− 15

10

3985

ns

5-1 A0 to A23 valid


D0 to D15 input at 0 waits

t

AD

2.0T

− 30

70 15970

ns

5-2 A0 to A23 valid

D0 to D15 input at 1 wait

t

AD3

3.0T

− 30

120 23970

ns

6-1

RD

fall

D0 to D15 input at 0 waits

t

RD

1.5T

− 30

45 11970

ns

6-2

RD fall

D0 to D15 input at 1 wait

t

RD3

2.5T

− 30

95 19970

ns

7-1

RD

low width

at 0 waits

t

RR

1.5T

− 20

55

11980

ns

7-2

RD

low width

at 1 wait

t

RR3

2.5T

− 20

105

19980

ns

8 A0 to A23 valid

RD

fall t

AR

0.5T

− 15

10

3985

ns

9

RD

fall

CLKOUT fall

t

RK

0.5T

− 20

5

3980

ns

10 A0 to A23 valid

D0 to D15 hold

t

HA

0

0

0 ns

11

RD

rise

D0 to D15 hold

t

HR

0

0

0 ns

12

WAIT

setup time

t

TK

15

15

15 ns

13

WAIT

hold time

t

KT

5

5

5 ns

Write cycle

Vcc

= 3.3 ± 0.3 V/fc = 4 to 40 MHz/Ta = −40 to 85°C

No. Parameter Symbol

Min

Max

f

SYS

=

20 MHz

(fc

= 40 MHz)

f

SYS

=

125 kHz

(fc

= 4 MHz)

Unit

1 OSC period (X1/X2)

t

OSC

25 250

25

250 ns

2 System clock period (

= T)

t

CYC

50 8000 50

8000 ns

3 CLKOUT

low

width

t

CL

0.5T

− 15

10 3985

ns

4 CLKOUT

high

width

t

CH

0.5T

− 15

10 3985

ns

5-1 D0 to D15 valid

WRxx

rise at 0 waits

t

DW

1.25T

− 35

28 9965

ns

5-2 D0 to D15 valid

WRxx

rise at 1 wait

t

DW3

2.25T

− 35

78 17965

ns

6-1

WRxx

low width

at 0 waits

t

WW

1.25T

− 30

33 9970

ns

6-2

WRxx

low width

at 1 wait

t

WW3

2.25T

− 30

83 17970

ns

7 A0 to A23 valid

WR

fall

t

AW

0.5T

− 15

10 3985

ns

8

WRxx

fall

→ CLKOUT fall

t

WK

0.5T

− 20

5 3980

ns

9

WRxx

rise

→ A0 to A23 hold

t

WA

0.25T

− 5

8 1995

ns

10

WRxx

rise

→ D0 to D15 hold

t

WD

0.25T

− 3

10 1997

ns

11

WAIT

setup time

t

TK

15

15

15 ns

12

WAIT

hold time

t

KT

5

5

5 ns

13

RD

rise

→ D0 to D15 output

t

RDO

0.5T

− 5

20

3995 ns

AC condition

• Output : High = 0.7Vcc, Low = 0.3Vcc, C

L

= 50 pF

Input :

High

= 0.9Vcc, Low = 0.1Vcc