Toshiba H1 SERIES TLCS-900 User Manual
Page 204
TMP92CM22
2007-02-16
92CM22-202
AD Conversion Result Register 0 Low
7 6 5 4 3 2 1 0
Bit symbol
ADR01
ADR00
ADR0RF
ADREG0L
(12A0H)
Read/Write R
R
After
reset
Undefined 0
Function
Stores lower 2 bits of AD
conversion result
AD conversion
data storage
flag
1: Conversion
result
stored
AD Conversion Result Register 0 High
7 6 5 4 3 2 1 0
Bit symbol
ADR09
ADR08
ADR07 ADR06 ADR05 ADR04 ADR03 ADR02
ADREG0H
(12A1H)
Read/Write R
After
reset
Undefined
Function
Stores upper 8 bits AD conversion result.
AD Conversion Result Register 1 Low
7 6 5 4 3 2 1 0
Bit symbol
ADR11
ADR10
ADR1RF
ADREG1L
(12A2H)
Read/Write R
R
After
reset
Undefined 0
Function
Stores lower 2 bits of AD
conversion result
AD conversion
data storage
flag
1: Conversion
result
stored
AD Conversion Result Register 1 High
7 6 5 4 3 2 1 0
Bit symbol
ADR19
ADR18
ADR17 ADR16 ADR15 ADR14 ADR13 ADR12
ADREG1H
(12A3H)
Read/Write R
After
reset
Undefined
Function
Stores upper 8 bits of AD conversion result.
9
8
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Figure 3.11.4 Register for AD Converter
Channel x
conversion result
ADREGxL
• Bits 5 to 1 are always read as 1.
• Bit0 is the AD conversion data storage flag <ADRxRF>. When the AD
conversion result is stored, the flag is set to 1. When either of the
registers (ADREGxH, ADREGxL) is read, the flag is cleared to 0.
ADREGxH