3.8.2 Operation

(1) Prescaler

The 5-bit prescaler generates the source clock for TMRB0. The prescaler clock (

φT0)

is a divided clock (Divided by 8) from selected clock by the register SYSCR1<GEAR1:0>
of clock gear.

This prescaler can be started or stopped using TB0RUN<TB0PRUN>. Counting

starts when <TB0PRUN> is set to 1; the prescaler is cleared to zero and stops
operation when <TB0PRUN> is cleared to 0.

Table 3.8.2 show prescaler output clock resolution.

Table 3.8.2 Prescaler Output Clock Resolution

Timer counter input clock

TMRB prescaler

TB0MOD<TB0CLK1:0>

Clock gear

selection

SYSCR1

<GEAR2:0>

φT1(1/2)

φT4 (1/8)

φT16 (1/32)

000 (1/1)

fc/16

fc/64

fc/256

001 (1/2)

fc/32

fc/128

fc/512

010 (1/4)

fc/64

fc/256

fc/1024

011 (1/8)

fc/128

fc/512

fc/2048

100 (1/16)

1/8

fc/256 fc/1024 fc/4096

(2) Up counter (UC10)

UC10 is a 16-bit binary counter that counts up according to input from the clock

specified by TB0MOD<TB0CLK1:0> register.

As the input clock, one of the prescaler internal clocks

φT1, φT4, and φT16 can be

selected. Counting or stopping and clearing of the counter is controlled by timer
operation control register TB0RUN<TB0RUN>. And an external clock from TB1IN0
pin can be selected in TB1MOD.

When clearing is enabled, the up counter UC10 will be cleared to zero each time its

value matches the value in the timer register TB0RG1H/L. Clearing can be enabled or
disabled using TB0MOD<TB0CLE>.

If clearing is disabled, the counter operates as a free-running counter.
A timer overflow interrupt (INTTBOF0) is generated when UC10 overflow occurs.