Table 1: af-300c standard specifications – GE Industrial Solutions AF-300C AC Drive User Manual

Page 21

Advertising
background image

AF-300C

GEK-85718

TABLE 1: AF-300C

STANDARD SPECIFICATIONS

inverter HP (400460 VAC)

Standard Applicable

30

OUTPUT:

Rated Capacity-460V

46

Rated Output

(Amps)

I

60

Rated Output Voltage

I

SPECIFIC

50

60

75

100

125

37

45

55

75

90

57

69

65

1 1 4

1 3 4

75

9 1

1 1 2

1 5 0

1 7 6

Type,

VAC

150 175 200 250 300

110 132 166 200 220

160 193 232 287 316

210 253 304 377 415

Rated Output Frequency

Overload Current Rating

50 120 Hertz Base Frequency

150% for 1 minute duration (inverse time characteristic)

POWER SUPPLY:

Rated input AC Voltage

3-Wire Type,

VAC

60 Hertz,

VAC

50 Hertz

Allowable Fluctuations

I

Voltage:

-15%; Voltage Unbalance: Within 3%; Frequency: +/-5%

Control System

I

Sinusoidal Wave PWM With Flux Control

Output Frequency Range

I 0.5 120 Hz (0.5 to 5.0 Hz start frequency; 50 to 120 Hz base frequency)

CONTROL:

Frequency/Temperature
Fluctuation (Stability)

Analog Setting Maximum frequency

(at

Digital Setting Maximum frequency +/-0.01% (at

to

Frequency Setting
Resolution

Analog Setting 0.1%

of maximum frequency

Digital Setting 0.1 Hz (0.01

Voltage/Frequency

Characteristics

Torque Boost

Voltage 320-460 VAC

(Adjustable independently for both

Base Frequency 50 to 120 Hz

voltage and frequency.)

21 selectable patterns plus energy conservation mode.

Acceleration/Deceleration

Chacteristics

Control Torque

0.2 to 3600 seconds, four

time settings available.

Three patterns available (Linear,

Curve, Logarithmic Curve)

Standard:

Regenerative Brake, (DC Link Pump-Up) DC injection Brake,
Starting Frequency of O-60 Hz at

Voltage for

O-l 0 Seconds Time

Optional:

Dynamic Brake, 100% (5% Duty Cycle).

Indicates rated

when rated output voltage is 440 VAC.

It is not possible for output voltage to exceed power supply voltage.
Consult distributor for operation above 120 Hertz.

2-5

Advertising