GEK-85718

input Side

Output Side

(Power Side)

(Electric Motor Side)

Symbol of
Instrument

Input Side Measuring
(Power Side)

Amperemeter
AR, S, T

Movable Core

Voltmeter
VR,

T

Rectifier Type
or Movable Core

Wattmeter
W R , T

mometer Type

Item

Measurement of Output Freq.

Terminals FM1 and FM2

Name of

Instrument

Kind of
lnetrument

DC Voltmeter

V

Movable Coil Type

Symbol of
Instrument

Output Side Measuring lnst

(Electric Motor Side)

Wattmeter
w u , w

dynamo-
meter Tvoe

Figure 7-2. MEASUREMENT LOCATIONS AND DEVICES EXAMPLE

MEASUREMENT POINTS AND METERS

Since the inverter input/output voltage and current

contains high frequencies, selection of the wrong
measuring device can lead to gross miscalculations.

When using a CT (current-detection transformer) to

measure the current, the amount of error will be large

if the frequency is low. Because of this, always use a
CT with as large a capacity as possible. See the fol-
lowing chart and Figure 7-2 for recommended meas-
urement devices.

RECOMMENDED MEASUREMENT DEVICE CHART

Item

Measurement Precision Measurement

Input

Tester

Moving-Iron type voltmeter

Input Current

Clamp Meter

Moving-Iron type ammeter

Input Power --

Electrodynamometer type wattmeter

Output Voltane

Tester

Rectifier type voltmeter

Output Current

Clamp Meter

Moving-Iron type ammeter

Output Power --

Electrodynamometer type wattmeter

7-3