Pre-trigger, Buffer size and segments – Teledyne LeCroy SierraNet M168 User Manual Ver.1.50 User Manual

Page 135

Advertising
background image

    

SierraNet M168 User Manual

133

Trigger and Filter Settings in Easy Mode

 Teledyne  LeCroy

Pre-Trigger

You can set the amount of data to capture before and after the trigger, as a 
percentage of pre‐trigger, between 0% and 100%. Position the pre‐trigger slider to a 
percentage. This feature allows the evaluation of bus activity leading up to and after the 
triggering Event. Figure 2.86:   illustrates the operation of pre‐trigger in data memory.

Pre‐trigger data is capture of the specified percentage of data prior to the triggering 
Event. It cannot be guaranteed and may be 0. This can occur when the triggering Event 
occurs before storing the required amount of pre‐trigger Event data. In such a case, the 
data display shows fewer than the specified data points prior to the triggering Event.

Figure 2.86: Pre-Trigger Example, 20% Pre-Trigger

Buffer Size and Segments

The Analyzer Settings panel has the Recording Buffer pane where you can set Number of 
Segments and the Segment Size. The defaults are one segment of 25MB. The total size 
used is automatically displayed for you. Setting multiple segments will allow to trigger on 
the first occurrence of the trigger condition, fill up the first segment, then automatically 
re‐arm the trigger and repeat the remaining number of segments specified. You can use 
the slider button or click the up or down arrow to change memory usage for recording 
trace data. (Minimum size of memory is 1MB. Maximum size of memory is dependent on 
the hardware.) (See 

Figure 2.25 on page 53

.) Enter an integer Num. of Segment, from 1 to 

32, then enter an integer Segment Size in kilobytes, up to the memory size in megabytes 
divided by the number of segments. The default 1. 

The New Project dialog opens with default settings to capture Everything on the bus and 
to Trigger On on Snapshot. (The analyzer captures everything immediately without 
triggering on anything in particular.)

Each time a trigger condition occurs, the system records a new segment. You can use a 
Snapshot or Pattern trigger, but not Manual Trigger. As the same trigger automatically 
repeats, the system makes the number of segments that you entered.