Analyzer Settings

52

 

 

SierraNet M168 User Manual

Device Settings

Click the Device External trig setting 

 icon to configure the Probe Calibration and the 

External Trigger settings for each device. See 

“Probe Calibration” on page 68 

and 

“External Trigger” on page 81

 for more information.

2.5.2

Port Status Pane

The Port Status panel displays the Port, Speed, and Functions (Trigger, Link, Frame and 
Error). Right‐click the pane and select the Reset button to reset the ports. 

Figure 2.22: Port Status Pane

Figure 2.23: Session Controller Pane

Channel Enable

 

Check the relevant ports to enable them.

Note:

If a Port ID check box has no check, the analyzer does not capture any patterns for that port. The 

system allocates trace memory for that port to its adjacent port, for example: P1 <‐> P2. 

Speed
The default speed is Autospeed. You can also select the port speed (from the front panel 
connectors of the Analyzer) of 10G using the SFP+ Ports P1 through P4 and P5 through 
P8.

Analyzer Settings in Ports

You can enable the ports, set the port speed.

2.5.3

Session Control Pane

Use the Session Control pane to run and stop a capture. You can also set the idle. 

Figure 2.24: Session Controller Pane

Start/Stop Session Button before recording is started

Start/Stop Session Button after recording is started