InFusion Scenarios

212

 

 

SierraNet M168 Protocol Analyzer User Manual

Symbol Detector(each has its own Embedded counter) X 4

Auto‐Neg Detector X 4

Counter X 12

Frame Detector X 8

Timer X 8

Frame Jammer X 8

Symbol Substitute X 16

Aut‐Neg Jammer X 4

Capture DWORD slot X 8

Insert/Save frame slot (up to 16K bytes) X 7

Insert BYTEs/Symbols inside frame (up to 128 bytes) X 8

Global Action Register X 8

State per sequencer X 256

Action Register per state X 8

Usage of Action Register: 

Each Counter in Global Rules = 1

Each Counter in State = 1

Each Timer in Global Rules = 2

Each Timer in State = 3

Other Actions = 1

The list of available resources for Fibre Channel is given below:

Symbol Detector (each has its own Embedded counter) X 4

Ordered‐set Detector (each has its own Embedded counter) X 8

Pattern (32bit) Detector (each has its own Embedded counter) X 12

Training Sequence Detector X 4

Counter X 12

Frame Detector X 8

Timer X 8

Frame Jammer X 8

Symbol Substitute X 4

Pattern/Orderded‐set Substitute X 12 (shared with Pattern detectors)

Training Sequence Jammer X 4

Capture DWORD slot X 8

Insert frame slot (up to 4K bytes) X 1

Insert DWORD inside frame (up to 64 bytes) X 8

Global Action Register X 8

State per sequencer X 256

Action Register per state X 8

Usage of Action Register: 

Each Counter in Global Rules = 2

Each Counter in State = 3

Each Timer in Global Rules = 2

Each Timer in State = 3

Other Actions = 1 