Multi-link triggering, Set timers – Teledyne LeCroy SierraNet M168 User Manual Ver.1.50 User Manual

Page 143

Advertising
background image

    

SierraNet M168 User Manual

141

Advanced Mode (User‐Defined)

 Teledyne  LeCroy

Multi-Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link, 
check the Multi Sequencer checkbox and select the link for setup from the Port tabs. 
When you select this option, you can define a sequencer per link (pair port). These 
sequencers are independent from each other and will be run separately on each link. 

Figure 2.92: Multi-Link Triggering Setup

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each state 
or continue from a timer set in the previous state. The timer defined for a particular state 

starts when entering that state. To set timers, click the Timer 

 icon in each state and 

define each of the timers in the Timer Setting dialog.

Figure 2.93: Timer Settings Dialog

Three timers are available. You have to set and start each timer in order to continue the 
next timer. For example, you have to start Timer 1, continue it, then set Timer 2 in order to 
continue it. It will not allow you to continue Timer 2 until you first set it.