Trigger and Filter Settings in Easy Mode

 Teledyne  LeCroy

can set the trigger position in the captured buffer as a percentage of the seg‐
ment size. Trigger point of 0% means the trigger point will be on the first packet 
in the buffer. (See 

“Trigger Position” on page 134

.) 

Figure 2.29: Trigger/Filter Settings Pane

2.6

Trigger and Filter Settings in Easy Mode

This mode allows you to operate the analyzer with minimum setup. In this mode, you can 
perform only a Trigger and Data capture. Use Easy Mode to get a comprehensive 
overview of your analyzer’s capabilities.

The Trigger and Filter settings dialog allows you to set the parameters for triggering on 
selected triggers and filtering in (including) or filtering out (excluding) selected patterns. 
The dialog box opens with default settings to capture everything on the bus. The analyzer 
captures everything immediately without triggering on anything in particular.

2.6.1

Trigger Tab

You can drag and drop patterns from the Trigger Library pane into the Active Pane. You 
can select the pattern and use the Add and Remove arrows to move patterns between 
the Patterns Library and the Active pane (see 

Figure 2.30 on page 58

). See 

“Trigger Setup” 

on page 131. 

You can copy a frame from the spreadsheet view and paste it in the Active 

Pane for triggering.


Set Trigger Position

Snapshot Mode

Click for Event Trigger

Trigger/Filter 
Settings