Trigger and Filter Settings in Easy Mode
Teledyne LeCroy
"don't care" and which ones have specific value. Some examples are given in the table
below.
If VI_READ_RQST is selected, the value for the "Device HDR" field will be "10" in binary
format as this field is a two‐bits field. This field is the last field in the "DF_CTL" field which
is an 8 bits field. For this specific frame, the value of "DF_CTL" will be "XXXXXX10" in
binary format and "X?" in hexadecimal format according to the conventions above.
Connect/Disconnect
Double‐click Connect/Disconnect to open the Connect Disconnect Pattern dialog.
Figure 2.58: Connect Disconnect Pattern Dialog
Check Connect and/or Disconnect, and enter the count of the expected number of
occurrences. Check the Check All box to select ports P1 through P8 or individually select
ports.
Symbol
Double‐click Symbol to open the Symbol Pattern dialog.
Hexadecimal Value
Length in bits
Equivalent Value in
Binary
"X1"
8 bits
"XXXX0001"
"X?"
8 bits
"XXXXXX10"
"?X"
8 bits
"110XXXXX"
"?"
2 bits
"XX"
"?"
3 bits
"11X"
"7"
3 bits
"111"
"7?"
8 bits
"01110XX1"