Setting the Network for RFC 2544 Tests

The network settings have to be adjusted to ensure that the test
can run.

NAT has to be disabled or the IP and MAC addresses of the
FrameScope Pro should be allowed to pass through.

Firewalls have to be disabled or should allow the IP and MAC
addresses of the FrameScope Pro to pass through.

ICMP ports need to be freed up for the network-under-test
(for information request and reply).

UDP ports 7 (slave UDP port) and 7777 (master UDP port)
needs to be vacated for the network-under-test.

During an RFC2544 test, the FrameScope Pro has a default
timeout duration after a MAC reset. If the peer does not
respond within the stipulated time, the RFC 2544 test will
not start and will result in a timeout. Different switches may
have different response times after a MAC reset. You should
select a suitable and appropriate timeout period for the
switches-under-test with reference to the equipment
requirements as supplied by the supplier or vendor.