Network Testing with the FrameScope Pro

2

N2620A User’s Guide

53

Setting Up the Master FrameScope Pro for RFC 2544 Tests

To perform an RFC 2544 test, you will need two FrameScope
Pro units, one as master and the other as slave, or a
FrameScope Pro and a loopback device. For initial settings on
the master FrameScope Pro, refer to

“General Settings for the

Master FrameScope Pro”

on page 49 before proceeding with the

procedure below.

1

If the slave destination is a FrameScope Pro, ensure that the
slave FrameScope Pro is ready for the RFC 2544 test. For the
slave FrameScope Pro settings, refer to

“Setting Up the Slave

FrameScope Pro for RFC 2544 Tests”

on page 62.

2

Select RFC 2544 Test on the Performance Tests menu.

3

Select Throughput, Latency, Frame Loss Rate, and Back-To-Back
RFC 2544 test options.

Press Suite to

load or create

new test suite.

Select RFC 2544

test options.

Press Settings to

set specific RFC

test parameters.