Network Testing with the FrameScope Pro

2

N2620A User’s Guide

59

Frame loss rate settings screen

Specify the frame length or

select Full Range to collect all

frames

For full duplex networks, you can

specify bidirectional testing.

For half duplex networks, upstream

and downstream can be tested

sequentially.

Select the frame direction to

measure (bidirectional is only

present for loopback)

Max Data Rate is used for initial

frame speed and performance

calculation. Enter the maximum data

rate of the network-under-test. If the

maximum data rate is unknown, the

link speed will be used.

Duration is the time taken (in seconds)

to transmit frames. For better results,

adjust the duration to load the

device-under-test sufficiently.

Select Full Range to measure

the frame loss rate specified

by the step size, or type in a

specific rate