Show switch – Allied Telesis AT-S63 User Manual

Page 95

Advertising
background image

AT-S63 Stack Command Line Interface User’s Guide

Section I: Basic Operations

95

SHOW SWITCH

Syntax

show switch module=

id

Parameters

id

Specifies the ID number of a switch in the stack.
You can specify only one switch at a time. To
view the module ID numbers, refer to “SHOW
STACK” on page 70
.

Description

This command displays a variety of information and parameter settings
about the switches in a stack. You can only view one switch at a time.
Since these parameter settings are only active on the master switch, the
command should only be used to view that unit. An example of the display
is shown in Figure 13.

Figure 13. SHOW SWITCH Command

This command displays the following information:

ˆ

Application software version and Application software build date - The
version number and build date of the AT-S63 Management Software.

ˆ

Bootloader version and Bootloader build date - The version number
and build date of the AT-S63 bootloader.

Switch Information:

Application Software Version ......... ATS63 v3.0.0
Application Software Build Date ...... May 14 2007 16:27:38
Bootloader Version ................... ATS63_LOADER v3.0.0
Bootloader Build Date ................ May 11 2007 16:25:19
MAC Address .......................... 00:21:46:A7:B4:43
VLAN Mode ............................ User Configured
Ingress Filtering .................... OFF
Active Spanning Tree version ......... RSTP
Mirroring State ...................... Disabled
Enhanced Stacking mode ............... Master
Console Disconnect Timer Interval .... 10 minute(s)
Web Server Status .................... Enabled
Telnet Server status ................. Enabled
Telnet insert NULL ................... OFF
MAC address aging time ............... 300 second(s)
Console Startup Mode ................. CLI
Multicast Mode ....................... Forward Across VLANs