How to Perform Advanced Tuning Techniques

MTS Series 793 Tuning and Calibration

Tuning Procedures

105

2. Display the controls for the control mode to be tuned.

Standalone FlexTest SE Controllers: Select Setup > desired Cascaded
PIDF
control mode > Tuning.

Automated Controllers:

A. In the Station Manager window’s Display menu, select Station

Setup.

B. In the Station Setup window navigation pane’s Channels, locate and

select the Cascaded PIDF control mode you are tuning.

C. In the Station Setup window, click

.

D. In the Tuning panel, click the Adjustments tab.

3. Adjust the PIDF controls for the control mode asscciated with the outer

control loop.

4.Save the outer loop tuning values.

Standalone FlexTest SE Controllers: Select Setup > Open/Save
Parameters
> <<Save>>.

Automated Controllers: In the Station Manager window’s File menu,
select Save Parameters.

5.Note the base control mode in the Tuning window.

6.Adjust the PIDF controls for the control mode associated with the inner control

loop.

7.Save the inner loop tuning values.

Standalone FlexTest SE Controllers: Select Setup > Open/Save
Parameters
> <<Save>>.

Automated Controllers: In the Station Manager window’s File menu,
select Save Parameters.

Advertising