MTS Series 793 Tuning and Calibration
How to Balance the Servovalve
Tuning Procedures
66
6. Balance the other servovalve of the dual valve pair.
A. Remove the blocking plate from the port of the other servovalve.
B. Reinstall the servovalve.
C. While observing Displacement Abs. Error on the Meters panel, adjust
the valve balance control for the other servovalve (Valve Balance 1 or
Valve Balance 2) until Displacement Abs. Error is zero.
7. Return displacement I Gain to its original setting.
Standalone FlexTest SE Controllers:
Select Tuning > Manual > I Gain
Automated Controllers:
A. In the Station Setup window, click
.
B. In the Tuning panel, click the Adjustments tab.