How to Perform Advanced Tuning Techniques

MTS Series 793 Tuning and Calibration

Tuning Procedures

91

6. Save the auto-tuning values.

Standalone FlexTest SE Controllers: Select Setup > Open/Save
Parameters
> <<Save>>

Automated Controllers: In the Station Manager window’s File menu,
select Save Parameters to save the New Values.

You may save auto-tuning values to an existing parameter set or to a new
parameter set.

Auto-tuning the force

control mode

1. Install a dummy specimen.

2. Set and enable the force feedback signal’s limits (typically just outside the

signal’s full-scale range).

Select Setup > Force > Limits

3. Set up auto-tuning parameters:

A. Select Tuning > Auto-Tuning.

B. For Control Mode, select displacement.

C. For Mode to Tune, select force.

Pressing the Run button will put the actuator in motion.

A moving actuator can injure anyone in its path.

Always clear the actuator area before pressing the Run button.

Note

While auto-tuning is in process you cannot changes channels or control
modes. Also, the active and auto-tuning signal’s tuning parameters will
be disabled.

WARNING

Advertising