MTS Series 793 User Manual
Page 55
Advertising
How To Warm Up Station Hydraulics
MTS Series 793 Tuning and Calibration
Tuning Procedures
55
7. Observe actuator response. If necessary, correct P Gain during warm up.
If the actuator responds in a sluggish manner, increase the P Gain setting. If
you hear an unusual or unexpected sound, decrease the P Gain.
Standalone FlexTest SE Controllers:
Select Tuning > Manual > P Gain.
Automated Controllers:
A. On the Station Manager window’s Display menu, select Station Setup.
B. Click the Channel Tuning icon to open the Tuning panel, the click the
Adjustments tab to display the P Gain control.
8. After 30 minutes, click Stop.
9. Remove hydraulic pressure from the station.
Advertising