How To Warm Up Station Hydraulics

MTS Series 793 Tuning and Calibration

Tuning Procedures

55

7. Observe actuator response. If necessary, correct P Gain during warm up.

If the actuator responds in a sluggish manner, increase the P Gain setting. If
you hear an unusual or unexpected sound, decrease the P Gain.

Standalone FlexTest SE Controllers:

Select Tuning > Manual > P Gain.

Automated Controllers:

A. On the Station Manager window’s Display menu, select Station Setup.

B. Click the Channel Tuning icon to open the Tuning panel, the click the

Adjustments tab to display the P Gain control.

8. After 30 minutes, click Stop.

9. Remove hydraulic pressure from the station.