MTS Series 793 User Manual

Page 69

Advertising
background image

How to Adjust Dither

MTS Series 793 Tuning and Calibration

Tuning Procedures

69

8. Increase Dither Amplitude until the feedback is smooth.

Standalone FlexTest SE Controllers:

Select Setup > Output > Dither Amplitude

Automated Controllers:

A. In the Station Manager window’s Display menu, select Station

Setup.

B. In the Station Setup window navigation pane’s Channels, locate and

select the channel whose servovalve dither you want to adjust.

C. In the Station Setup window, click

.

Three-stage valves: In the Drive panel, click the Valve tab.

Method 2:

1. Select an access level of Tuning.

2. Remove any specimen.

3. Apply hydraulic pressure to the station.

4. Increase Dither Amplitude until you can hear the dither and then decrease

Dither Amplitude until the noise goes away.

Dither Frequency

adjustment

In addition to Dither Amplitude, your Controller is equipped with a Dither
Frequency
control.

The default dither frequency is 528 Hz, which is effective for most applications,
and should not require adjustment. However, if the dither frequency begins to
resonate with test frequencies, adjustment may be necessary.

Advertising