Where to find valve balance procedures – MTS Series 793 Utility Software User Manual

Page 30

Advertising
background image

The inner loop (like the outer loop), has gain and rate controls that can be adjusted to optimize
performance. The inner-loop is tuned at system installation, and requires periodic fine tuning when
the outer-loop becomes sluggish.

Item

Number callout in graphic

Feedback

1

Outer Loop

2

Inner Loop

3

Hydraulic Service Manifold (HSM)

4

Hydraulic Power Supply

5

Control Signal

6

493.15 Valve Driver

7

Program Command

8

The innerloop (proportional) gain and rate (derivative) adjustments are the same types of
adjustments as the proportional and derivative gain adjustments of the outer-loop tuning controls.

Where to Find Valve Balance Procedures

Mechanical valve-balance procedures

For two-stage servovalves, the mechanical valve balance procedure is included in the Series 252
Servovalve Product Manual (PN 011-182-906), which is typically included in the system
documentation set.

16 MTS Series 793 Utility Software

Create and Edit an HWI File

Advertising