CAN Bus Interface

Note:

CAN Bus interface support is not available for MTS FlexTest SE Controllers.

CAN Bus Interface Requirements

A controller area network (CAN) bus interface requires a CAN bus controller mezzanine card that
is installed on a processor board.

The CAN bus card can include multiple CAN controllers that are configured and assigned
independently. The mezzanine card provides a network connector for each CAN bus port.

CAN Bus Interface Setup

1. Open the .hwi file.

2. Click the Controller icon, and then click the Miscellaneous tab.

3. From the # of CAN Bus Interfaces list, select 1.

A series of CAN bus icons appear under the processor icon.

4. Configure the CAN bus interface as shown in the following table.

Description

Item

Type: Select the model number of the CAN bus controller
mezzanine card that is installed on the processor board.

CAN Bus Icon

Each port icon represents a separate CAN bus controller port that
you can configure independently.

Port Icon(s)

Baud Rate: Enter baud rate for the CAN bus port’s RS-485 interface.

Frame Format: select the frame (message) format required by the
CAN. Selections include Basic or Extended.

Modbus Interface Settings

A Modbus Interface consists of a networked Modbus node that connects to the controller processor
through an Ethernet network switch. A Modbus node includes a Modbus chassis (DIN rail) populated
with various modules including an Ethernet TCP/IP Fieldbus Coupler.

Description

Item

# of Modbus Interfaces: Enter the number of Modbus interfaces.
Each Modbus interface (Modbus node) consists of a DIN rail,
modules, and an Ethernet TCP/IP Fieldbus Coupler.

Miscellaneous Tab (Controller
icon)

MTS Series 793 Utility Software 83

HWI Hardware Settings