Model 493.74 hsm transition board – MTS Series 793 Utility Software User Manual

Page 88

Advertising
background image

Description

Item

Off-low-high–three HPU control buttons (Off/Low/High) will appear
on the Station Manager Station Controls panel.

First On: True: Indicates that the first HSM turned on activates the
HPU. False: Setting First On and Last Off to False allows the HPU
to turn on independent of HSM power. Setting First On and Last Off
to True allows HSM Low selection to activate HPU high without
pressing the HPU buttons.

Last Off: True: Causes the last HSM turned off to turn off the HPU.

Visible: True: Indicates whether or not the HPU button is visible on
the control panel. Changing Visible to False turns off the HPU button
display on the Station Manager window, provided both First On and
Last Off are True.

Model 493.74 HSM Transition Board

Description

Item

The hydraulic control definition assigns the Hydraulic Power
Unit (HPU) transition board and each Hydraulic Service

493.74 HSM transition board icon

Manifold (HSM) transition board to their appropriate rear panel
connectors. Each of the two HSM transition boards allowed in
your system can support up to two HSM stations.

Transition Slot: Specifies the transition slot where this board
is installed.

Changing this name may invalidate existing station
configurations.

Hydraulic Interface icon

Name: Describes this resource as it will appear in Station
Builder resource lists when opened against an .hwi file.

Connector: J28A or J28B.

Type: Solenoid, On/Off Solenoid, Proportional.

If you select On/Off Solenoid, only 2 HSM control buttons
(Off/On) will appear on the Station Manager Station Controls
panel. For the other types, 3 HSM control buttons will appear
(Off/Low/High).

If you select Proportional, you configure the proportional output
with the controller software. The output signal can be ramped
from 20 mA (minimum) to 700 mA (maximum) which
corresponds with 50 psi (0.4 MPa) and 3000 psi (21 MPa). By
default, low pressure is factory set at 750 psi (5.25 MPa) and
high pressure is set at 3000 psi (21 MPa).