Remote station control (rsc) settings, How to add remote station controls (rsc) – MTS Series 793 Utility Software User Manual

Page 95

Advertising
background image

Remote Station Control (RSC) Settings

The RSC can not be used with Series 494 hardware.

Note:

The FlexTest SE and FlexTest 40/60/100/200 Controllers do not support RSCs.

Description

Item

The Remote Station Controller (RSC) is a table-top, stand-mounted,
or hand-held device that is primarily used for specimen installation

Remote Station Control
icon

and the starting and stopping of tests. A GRES III board is needed
to support an RSC in your system.

Remote Station Controllers are not available with the optional 6 or
8-station system configurations

The FlexTest IIm/CTC controller can support an RSC for each station
(for a total of four RSCs) on the 498 RS-485 Transition Board.

Name: Specifies the desired resource name. Changing this name
will not cause file conflicts.

Host Port: The host port entry specifies which Com port on the GRES
III plug-in board the Model 493.71 Serial Interface transition board
port is mapped to. (This determines which port the RSC must be
plugged into.)

Interlock: Specifies the interlock chain number. By default, the
interlock chain number and the RSC number are equal. If you want
to map an RSC with a different interlock chain (if available), change
this value.

How to Add Remote Station Controls (RSC)

Before you can add RSC or Handsets, you must add a GRES III board or 494.47 Dual
UART/Encoder mezzanine card.

Note:

FlexTest SE Controllers do not support Remote Station Controls (RSCs).

1. Select Controller in the tree view pane.

2. Click the Miscellaneous tab.

3. Specify the number of remote station controls. Each RSC is associated with a specific Host

Port.

4. On the Remote Station Control Properties tab, select the correct HOST PORT.

MTS Series 793 Utility Software 81

HWI Hardware Settings