MTS Series 793 Utility Software User Manual

Page 63

Advertising
background image

How to Add Accelerometer Compensation to a Model
493.21B/493.25 DUC

This procedure only applies to Model 493.21B and 493.25 DUCs.

1. Add a 493.48 Accelerometer Conditioner board to the .hwi file.

2. Right-click the DUC icon and select Add Accelerometer Compensation.

A 493.48 Accel Input resource appears as an Auxiliary Input on the DUC Properties tab.

3. If necessary, change the hardware resource name to match the Accel Input where the

accelerometer is physically connected.

How to Add a DI/O Load Washer to a Model 493.21B/493.25
DUC

This procedure only applies to Model 493.21B and 493.25 DUCs.

1. Add a 493.72 DI/O board resource to the .hwi file.

2. Right-click the DUC icon and select Add DIO Load Washer.

A DI/O Load Washer icon appears below the DUC icon.

3. Click the DI/O Load Washer icon and verify that the hardware resource names that appear in

the Zero Bit, One Bit, and Enable boxes are correct.

4. If the hardware resource names are not correct, change the hardware resources names in

these boxes to match the Digital Inputs where these signals are physically connected.

5. If you want to assign custom names to each range, use the Hwi File Editor application to change

the range names to match the range names that you will use in the Station Manager application.

Note:

The range names that appear in the DI/O Load Washer Properties tab must match the
range names assigned in the Sensor tab in the Station Manager application.

How to Add a Serial Load Washer to a Model 493.21B/493.25
DUC

This procedure only applies to Model 493.21B and Model 493.25 DUCs.

1. Add a serial comm resource to the .hwi file (for example, 498.71B GRES III or Ramix serial

card).

2. Right-click the DUC icon and select Add Serial Load Washer.

A Serial LoadWasher icon appears below the DUC icon.

3. Configure the Serial LoadWasher.

MTS Series 793 Utility Software 49

HWI Hardware Settings

Advertising