MTS Series 793 Utility Software User Manual

Page 79

Advertising
background image

Description

Item

Input Filter Settings:

Filter Type: Used to select the type of digital filter used to filter the
input signal. Filter selections include: Disabled, Bessel, Butterworth,
and Elliptical. (Default=Bessel, 300 Hz.)

Filter: This is the frequency where the filter, selected in the Filter Type
box, attenuates the signal by 3 dB.

Low frequency limit = >0 Hz (A setting of 0 disables the filter.) High
frequency limit = 1/2 the system rate.

Important:

Rotary SSI/Gurley devices with Turns Counting = False: filtering
may be undesirable because as the signal is filtered, the angle
step that occurs every 360 degrees causes ringing due to the
high-frequency content of the step. Filtering occurs normally if
the encoder is operated in a range that does not include the
angle step.

MTS Series 793 Utility Software 65