MTS Series 793 Utility Software User Manual

Page 71

Advertising
background image

Description

Item

CAUTION:

Your controller’s hardware interface file (.hwi) includes
options to clamp the servovalve when a hydraulic
interlock occurs (these options cause the actuator to
stop, fully extend, or fully retract). However, if the
servovalve is imbalanced, it may move unexpectedly
when clamped.

Unexpected actuator movement can cause injury and
equipment damage.

Before enabling the valve clamp feature, ensure that the
servovalve is balanced.

Mode: Select Single to configure this card to drive a single servovalve;
select Dual to configure this card to drive dual servovalves.

2SVD Analog Output icon

Range: Enter the full-scale current value for the servovalve driven
by this card (100 mA maximum per output).

Model 494.21 Multi-Range DUC with Acceleration
Compensation Card HWI Settings

This card combines a DUC and an accelerometer compensation input on a single card. The
summing of the two signals is done on the card based on settings in your test application.

Description

Item

Describes the valve driver/DUC mezzanine card.

494.21 DUC mezzanine card
icon

Connector: Describes the front-panel I/O Carrier connector
assigned to this input.

494.xx Analog Input icon

Name: Describes this resource as it will appear in Station Builder
resource lists when opened against an .hwi file.

Changing this name may invalidate existing station configurations.

Filter Type: Used to select the type of filter used to filter the digital
output of the DUC. Selections include: Disabled, Bessel,
Butterworth, and Elliptical.

Filter: This is the frequency where the filter, selected in the Filter
Type box, attenuates the signal by 3 dB. A setting of zero
disables the filter. (Default=Bessel, 300 Hz.)

High Speed Data:

MTS Series 793 Utility Software 57

HWI Hardware Settings

Advertising