Interconnect Diagrams

115

Power Interconnect Diagrams

This is the power wiring diagram with 24V dc control string for
2098-DSD-005x-xx, 2098-DSD-010x-xx, and 2098-DSD-020x-xx
Ultra3000 drives (non-SERCOS drives only). To avoid a separate 5V dc
auxiliary logic power supply, the 24V to 5V converter breakout board
(catalog number 2090-U3CBB-DMxx) is used to wire the control
interface (CN1) connector. For the control string diagram with 120V ac
input refer to the figure on page 128.

For SERCOS drives, input line contactor is part of the PLC program
and output control.

Typical Power Wiring of Ultra3000 (230V) System

TB1

DC+

DC-

L1

L2/N

U

V

W

L2/N

L1

CN1

43

44

3

2

43

44

CN1

2098-DSD-005x-xx,

2098-DSD-010x-xx, and

2098-DSD-020x-xx

Ultra3000

Digital Servo Drives

Note 13

DC Bus Connections
for Active Shunt Module
(refer to page 119 for example)

AC Input Power
Connections

Motor Power
Connections

M1*

Note 8

Single-phase

AC Line Filter

Note 7

Input Fusing*

Note 4, 5

Single-phase AC Line

50/60 Hz

Fused Disconnect

or Circuit Breaker*

Note 1

Isolation

Transformer*

Note 2

Chassis

Bonded Cabinet

Ground Bus*

Terminal

Blocks*

Note 3

To additional

Ultra3000 drive

Three-phase

Motor Power

Connections

Note 12

Cable Shield

Clamp

Note 9

* Indicates User-supplied Component

STOP*

START*

CR1*

CR1*

CR1*

M1*

Refer to Attention statement (Notes 10, 11)

24V dc

N.O. Relay Output+

N.O. Relay Output-

Aux Logic Power In +5V

Aux +5V Common

Note 23

Note 22

From CN1 Breakout
Board with 24V to 5V
Aux Power Converter
(2090-U3CBB-DMxx)

Single-phase Input

100-240V ac RMS