COS Message Format

The XM-123 COS message contains six bytes of data as defined in the table
below. The COS data can also be requested explicitly through Assembly
Object (Class ID 0x4), Instance 100 (0x64), Data Attribute (3).

XM Status Values

The following tables describe the XM Status values that are included in the
COS messages.

XM-123 COS Message Format

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Relay 1
Status

Setpoint
Multiplier
Status

Alarm 2 Status

Alarm 1 Status

1

Relay 2
Status

Reserved

Alarm 4 Status

Alarm 3 Status

2

Relay 3
Status

Reserved

Alarm 6 Status

Alarm 5 Status

3

Relay 4
Status

Reserved

Alarm 8 Status

Alarm 7 Status

4

Relay 5
Status

Reserved

Alarm 10 Status

Alarm 9 Status

5

Reserved

Reserved

Alarm 12 Status

Alarm 11 Status

Alarm Status Descriptions

Alarm Status Value

Description

0

Normal

1

Alert

2

Danger

3

Disarm

4

Transducer Fault (Sensor OOR)

5

Module Fault

6

Tachometer Fault

7

Reserved

Setpoint Multiplier Status Descriptions

Setpoint Multiplier Status Value Description

0

Not Activated

1

Activated

Advertising