Connecting a passive transducer – Rockwell Automation 1440-VAD02-01RA XM-123 Aeroderivative Module User Manual

Page 39

Advertising
background image

Publication GMSI10-UM003D-EN-P - May 2010

31

Connecting a Passive Transducer

The figures below show the wiring of a passive transducer, such as a velocity
sensor, to the terminal base unit.

Figure 2.21 Velocity Sensor to Channel 1 Wiring

ATTENTION

You may ground the cable shield at either end of the cable.
Do not ground the shield at both ends. Recommended
practice is to ground the cable shield at the terminal base
and not at the transducer. Any convenient Chassis terminal
may be used (see Terminal Block Assignments on page 18).

IMPORTANT

The module does not power the sensor. It measures only
the input voltage.

TYPICAL WIRING FOR COIL-BASED VELOCITY SENSOR
TO XM-123 AERODERIVATIVE MODULE CHANNEL 1

Cable shield not
connected at this end

Shield

0

16

Channel 1 Input Signal

Signal Common

37