Rockwell Automation 1440-VAD02-01RA XM-123 Aeroderivative Module User Manual

Page 91

Advertising
background image

Publication GMSI10-UM003D-EN-P - May 2010

83

Indicators

7 LEDs Module Status - red/green

Network Status - red/green
Channel 1 Status - yellow/red
Channel 2 Status - yellow/red
Tachometer Status - yellow/red
Setpoint Multiplier -yellow
Relay - red

Signal Conditioning

Tracking Filter

Bandpass Filter

Frequency Range

Resolution

Amplitude Range

Integration

Low Pass Filters

High Pass Filters

Tracked Speed Multiple: 0.1 to 20.0 times
the measured (tachometer) RPM
Constant Q: 1 to 200 or,
Constant Bandwidth: 0.1 to 25 Hz
Roll Off: -36 dB per octave (typical)

Minimum Frequency (25 to 1000 Hz)
Maximum Frequency (100 to 5500 Hz)
Roll Off: -60 dB per octave

1 Hz to 20 kHz

A/D Conversion: 24 bits
Dynamic Range: <80 dBfs
(0.01% fs), -90 dBfs (typical)

Dependent on sensitivity

One level provided in hardware

Independently configured per channel
Optional Overall measurement LP filter
(200 Hz to 20 kHz)
Roll Off: -24 db per octave

Independently configured per channel
Integration Off: 1, 5, 10, 40, 1000 Hz
Roll Off: -30dB per octave for the 1 Hz HPF,
otherwise -24 dB per octave
Integration On: 5, 10, 40, 1000 Hz
Roll Off: -30 dB per octave for the 5 Hz HPF,
otherwise -24 dB per octave

Measured Units g um

ips volt
mm/s psi
mils Pa

XM-123 Technical Specifications

Product Feature

Specification

Advertising