Instance attributes, Services, Instance attributes services – Rockwell Automation 1440-VAD02-01RA XM-123 Aeroderivative Module User Manual

Page 143

Advertising
background image

Publication GMSI10-UM003D-EN-P - May 2010

135

Instance Attributes

Services

1

Attributes can only be set while the device is in Program Mode. See the description of the Device Mode Object
for more information.

Table C.44 Speed Measurement Object Instance Attributes

Attr ID

Access
Rule

Name Data

Type

Description

Semantics

3

Get

Speed Value

REAL

The measured speed
value.

CPM

4

Get

Status

BOOL

Indicates if a fault or
alarm has occurred.

0 = Operating without alarms or
faults.
1 = Alarm or fault condition
exists. The Speed Value
attribute may not represent the
actual field value.

5

Get

Maximum
Speed

REAL

The maximum (peak)
measured speed value
(positive or negative)
since the most recent
reset.

CPM

12

Get/Set

Time Constant

UINT

The time constant value
used for exponential
averaging of the Speed
Value
(a low pass
filter/output smoothing
filter).

Milliseconds

Table C.45 Speed Measurement Object Services

Service
Code

Class/Instance Usage

Name

Description

05

h

Instance

Reset

Clears Maximum (Peak)
speed to 0.

0E

h

Instance

Get_Attribute_Single

Returns a single attribute.

10

h

Instance

Set_Attribute_Single

Sets a single attribute.

1

Advertising