Triggered Trend Parameters

Parameter Name

Description

Values/Comments

Enable Triggered Trend
Measurements

Enables/disables the triggered trend measurements.
Select to configure the triggered trend
measurements.

Check to enable.
Clear to disable.

Select Measurements

Sets the measurements to be collected and stored in
the module.

More than one measurement can be
selected.

Important: Make certain to check
your filter selection (Tracking Filter
or Bandpass Filter).

The XM-123 can produce either the
bandpass or tracking measurements
depending on which filter is selected.
If you select a band or tracking
measurement that is not being
produced by the module, a trend of
zeroes will be stored for that
measurement.

For example, if you select the "Ch1
Band" measurement but the
Bandpass Filter for Channel 1 is not
selected, the module will store zeroes
in the trend for the CH1 Band
measurement.

Number of Records

The maximum number of measurement sets that can
be collected in the trend buffer. The measurement
sets make up the trend data.

The Number of Records is
automatically calculated based upon
the number of Trended
Measurements
selected.

Latch Enable

Determines whether the trigger trend is latched or
unlatched.

Latched means that subsequent triggers are ignored
after the initial trigger. This prevents the trend data
from being overwritten with new data until the
trigger is manually reset (click Reset Trigger button).

Unlatched means that the trend data is overwritten
with new data every time a trigger occurs.

Check means latched
Clear means unlatched

Relay Number

Sets the relay that triggers the trend to be collected.

None means that the trend can only be
triggered manually or by a trigger
event (for example, XM-440).

Relay Numbers 1 through 5 are either
relays on the Expansion Relay module
when it’s connected to the module or
virtual relays.

Note: The relay must be enabled.
Refer to Relay Parameters on page 64.

Advertising