84

Measured Parameters

Speed

Overall

Transducer Bias Voltage

Bandpass Filter

Tracking Filter

RMS
Peak (true or calculated)
Peak to Peak (true or calculated)
User configurable in software

Band Value

Tracked Vector Magnitude
Tracked Vector Phase

Data Buffers

Trend Buffer

Speed Buffer

Stores a set of records containing measured
parameters in response to a trigger event.
Trend Record: 1 to 9 parameters
Trend Interval: 1 to 3600 seconds
Trigger: Trend is stored when a specified
relay on the XM-123 module is activated, or
by a trigger event (for example, DeviceNet
command from a controller or host)
Capacity: 227 to 2048 records depending on
the number of parameters stored

Stores a startup/coast-down trend of
measurement parameters in response to
changes in speed.
SU/CD Record: 2 to 9 parameters
SU/CD Interval: 1 to 3600 RPM
Trigger: Startup collects data in increasing
rpm direction only; Coast-down collects
data in both increasing and decreasing
directions.
Capacity: 186 to 512 records depending on
the number of parameters stored
SU/CD buffer may be latched to preserve
the initial trip data in the event of
subsequent trips.

The data collected in the buffer is user
configurable.

XM-123 Technical Specifications

Product Feature

Specification

Advertising