Page 1-6

Chapter 1 General Description

DISPLAY

Display Type Mono

CCFL backlit STN Liquid Crystal Display (5.0 inch) with touchscreen control.

Resolution Mono

240 (H) X 128 (V) pixels.

Display Type Color

CCFL backlit Active Matrix TFT Liquid Crystal Display (5.6 inch) with touchscreen control.

Resolution Color

320 (H) X 240 (V) pixels.

Display Modes

Graphics (Trending vertical or horizontal), Bar Graphs (vertical or horizontal), Digital Meter,
Alphanumeric Alarm and Event data or combinations on a split screen. Review trended data.

Virtual Chart Speed

Programmable: 0.5 in/hr to 600 in/hr (10 mm/hr to 15,000 mm/hr)

Virtual Chart Scales

2 sets of 8 scales

Display Windows

Time/Date, Graphics (Bars, Large Digital, Trends), Disk Status, System Status, Menu Button Bar,
Unit Identification, Alarms/Events.

Power Requirements

100 to 240 Vac, 50/60 Hz. 35 VA max. Optional 24 Vdc + 15%

Power Fail Protection

Programmed parameters stored in non-volatile memory. Clock battery backed. Data retention
time without power > 12 months.

OTHER

Operating Range

-10°C to 50°C, 10% to 80% RH (5°C to 40°C for floppy media)

Safety

Meets the requirements of UL-3111-1 and EN61010- 1 when installed in accordance with the
instruction in this manual.
UL and cUL approved - File No. E175096

EMC

Meets the requirements of EN61326:1998 and CE directive 89/336/EEC

Input Voltage

100 to 240 Vac, 50/60 Hz or 125 Vdc @ 35VA max.

Weight

Approx. 7 lbs (3.2 kg) - weight will vary depending on options installed