Chapter 2 Installation and Wiring

2.2.1 Panel Mounting

The Recorder should be mounted in a vertical panel to ensure proper operation. Ensure you have the proper
clearances and proceed as follows:

2.2.1.1 Cut a panel opening 5.43” x 5.43” [138 mm x 138 mm].

2.2.1.2 Remove any packaging material from the Recorder. Always handle the unit carefully to avoid

damaging the LCD display or scratching the display surface.

Figure 2-2 Front Panel Insertion

2.2.1.3 Remove the locking bars from the Recorder enclosure and ensure the gasket is not twisted on the

enclosure.

2.2.1.4 Insert the Recorder rear end first, into the panel opening from the front of the panel. Ensure the

gasket is between the front bezel of the Recorder and the front panel.