Edit Float Switch Parameters dialog

Enable Select this checkbox in the Float [1 and/or 2] section
to activate the options for the float you want to edit.

Alarm Select the kind of alarm you want to initiate when the
flow reaches the corresponding depth level.

Note: You may designate only one alarm for each device
when configuring the devices for a FlowAlert monitor.
However, the alarms can be distributed among the float
switches and the pressure depth sensor as applicable and
appropriate.

Debounce Use the arrows to designate the minimum amount
of time, following a change in state, the float must remain in a
new state to activate an alarm or indicate a return to normal.

Trip Point Enter the elevation at which the float changes
states.