Problem

Float switch does not change status when flow depth
recedes.

Possible

Cause

Float switch may be unable to return to closed (vertical)
position due to obstruction or debris.

Connector may not be properly engaged.

Float switch may be malfunctioning.

Possible

Solution

Inspect float switch in manhole for obstructions or debris
and make necessary modifications.

Inspect connection between float and monitor.

Replace float switch.

Problem

A float error occurs.

Possible

Cause

Connector may not be properly engaged (attached). An
error will not occur if two float switches are in use, but
only once the connector becomes disengaged.

Float switch may be malfunctioning.

Possible

Solution

Inspect connection between float and monitor.

Replace float switch.

Problem

The float state changes, but no alarm occurs.

Possible

Cause

Connector may not be properly engaged.

Float switch may be malfunctioning.

Possible

Solution

Inspect connection between float and monitor.

Replace float switch.