3-28

ADS FlowAlert Manual

Note: Make sure the submerged portion of the band is
flush with the pipe wall. If it is not, remove the band and
conform the band to the pipe.

8. Install a ¼-inch x 2 ¼-inch anchor bolt, washer, and nut below

the flow surface 1 to 3 inches away from the pressure depth
sensor on each side. This will hold the sensor securely against
the pipe wall and prevent the end of the band from twisting in
the flow or catching debris.

9. Conform the portion of the band above the flow surface to the

pipe wall, and install an ¼-inch x 2 ¼-inch anchor bolt, nut,
and washer every 12 to 24 inches up to the top of the band.

Completed ½-band mount in pipe

10. Measure the physical offset for the pressure depth sensor (i.e.,

the vertical distance from the bottom of the sensor to the
bottom, center of the pipe).

Note: This value will be necessary when configuring the
monitor using the Profile software.

11. Run the sensor cable from the sensor location in the pipe to the

monitor location in the manhole according to the instructions
on page 3-36.