Wiring the telephone cable to the monitor – ADS Environmental Services FlowAlert QR 775011 A2 User Manual

Page 96

Advertising
background image

4-28

ADS FlowAlert Manual

Stripping ½ inch of insulation from each wire

5. At the pedestal end of the cable, fold over both exposed wires

(doubling the thickness). Insert each wire into a non-insulated
#10 ring terminal lug (22-18 gauge), and crimp the wires to the
lugs.

Wiring the Telephone Cable to the Monitor

After preparing the telephone cable, wire the telephone cable to the
monitor in the following way:

Note: Wiring the telephone cable to the monitor requires
an intermediate cable (External Power/Phone Cable - ADS
p/n 5000-0697) supplied by ADS when ordering a
FlowAlert monitor equipped for landline communication

1. Unpack the FlowAlert phone cable (ADS p/n 5000-0697). This

is the same cable as the RainAlert II phone cable and the
FlowShark External Power Cable.
The pigtail consists of two
bundled pairs: green/white and red/black. If these soldered
junctions must be modified or stripped to simplify the phone
junction process, keep the pairs together. Although they do not
require soldering, the green/white and red/black pairs must