Pressure Depth Sensor and Float Switch Installation 3-31

Installing the Sensor in the Manhole
or Pump Station Wet Well

This section includes the procedure for mounting the pressure depth
sensor to the wall of a manhole or pump station wet well. Install the
sensor in the following way:

1. Gather the parts listed on the following table:

Quantity

Description

ADS Part Number

1

FlowAlert monitor

6000-FAW or -FAL

1

monitor mounting bracket

I40-0003

1

pressure depth sensor with two 4-40 x

5/16-inch stainless steel screws

3704-0010 (5 psi)

3704-0015 (15 psi)

3704-0016 (30 psi)

1

replacement dryer tube

3704-0032

1

direct connection cable

5000-0601

15

11-inch cable tie

I05-0003

25

4-inch cable tie

I05-0001

15

8-inch cable tie

I05-0002

10

anchor cable tie

I05-0004

2

¼-

× 2 ¼-inch anchor bolt (with 7/16-

inch nut and washer)

I01-0002

1

3/8-

× 2-inch stud

I01-0009

1

3/8-inch x 3-inch anchor bolt and nut

I01-0003

2

3/8-inch x 1-inch stainless steel hex

bolts

I01-0001

4

3/8 – 16 stainless steel hex nuts

I15-0002

5

3/8-inch stainless steel flat washers

I55-0001

2

4-40

× 5/16-inch screw

I35-0001

8

6-32 washer

I55-0002