Pressure Depth Sensor and Float Switch Installation 3-37

Warning: Over-tightening the cable ties may damage the
sensor cable.

2. Secure the cable with a cable tie and plastic anchor every 18 to

24 inches along the pipe crown (when necessary) from the ring
to the manhole. If plastic anchors will not serve as adequate
anchors based on the structure of the pipe, install ¼-inch x 2
¼-inch bolts instead.

3. Secure the cable every 18 to 24 inches up the side of the

manhole to the monitor location. A loose cable could present a
manhole safety hazard or increase the potential for sensor or
monitor damage. If plastic anchors will not serve as adequate
anchors based on the structure of the manhole wall, install ¼-
inch x 2 ¼-inch bolts instead.

Securing the sensor cable along the pipe and into the manhole