ADS Environmental Services FlowAlert QR 775011 A2 User Manual

Page 120

Advertising
background image

5-16

ADS FlowAlert Manual

 Select Environmental Services > Support > Client

Services.

 Click on the Download pressure coefficients… link.

 Right-click on the year in which the sensor was

manufactured, and select the Save Target As option.

 Rename the file to reflect the following format:

pressure.xx, where xx represents the last two digits of the
year in which the sensor was manufactured. You must
remove the .txt extension.

 Save the file to the appropriate location in the local file

system.

Pipe Height This field displays the pipe height at the monitor
location. This parameter is not editable from this location.

Physical Offset Enter the physical offset for the pressure
depth sensor based on the installation location. ADS
recommends measuring this distance manually during the
monitor installation or confirmation process. Profile defaults
to 0 inches.

Pipe When the sensor is installed in a pipe, enter the

vertical distance from the bottom of the sensor to the
bottom center of the pipe.

Manhole/Wet Well Wall When the sensor is mounted to

a manhole or wet well wall, enter the vertical distance from
the manhole invert (or bottom) to the nose of the sensor.

Depth Alarms – High Edit the device to ensure the
FlowAlert initiates a high depth alarm when a pressure depth
reading reaches or a exceeds a specified depth in the following
way:

Enable Select this checkbox to activate the high depth

alarm options.

Trigger Enter the pressure depth reading at or above

which you want the FlowAlert to initiate a high depth
alarm.

Advertising