Quantity

Description

ADS Part Number

4

6-32

× 1-inch machine screw

I35-0004

4

6-32

× 5/16 inch nut

I15-0003

15

plastic push mounts

I01-0006

1

sensor mounting strap

700-100238-00

2. Gather the following tools and supplies:

 Battery-powered hammer drill with assorted bits –

including the following, at a minimum:

 3/8-inch x 4-inch (minimum length) masonry bit

 ¼-inch masonry bit (F35-0018)

 5/16-inch carbide-tipped drill bit (include smaller bits)

 4-pound hammer

 Rubber mallet

 Wrenches

 Screwdrivers (flathead and Phillips head of assorted sizes)

 3/8 – 16 thread tap

 Diagonal wire cutters

 Folding carpenter’s rule with a brass slide

 Rubber stretch tape

3. Determine the appropriate location on the manhole or wet well

wall to mount the sensor.

4. Hold the pressure mounting strap (ADS p/n 700-100238-00)

vertically against the wall at the selected location, and mark the
wall through the top hole of the strap.