ADS Environmental Services FlowAlert QR 775011 A2 User Manual

Page 80

Advertising
background image

4-12

ADS FlowAlert Manual

Note: If you cannot get the stake down to the depth
required to align the holes together, use a hacksaw to
remove some of the length of the stake and drill new holes
with a 3/8-inch bit.

8. Run the antenna cable through the bottom of the base into the

trench.

9. Lay the cable in the trench, and run the cable through the pre-

drilled hole in the corbel.

10. Coil the slack antenna cable and secure it away from the other

cables in the manhole. Slack enables the technicians to remove
the monitor from the manhole for maintenance or service
activities with the antenna cable still connected. Do not bundle
the antenna and sensor cables together!
This can significantly
diminish antenna and sensor signal strength, disrupting
communications and limiting sensor accuracy.

Note: To prevent damage to the cable and antenna, do not
kink or bend the antenna cable when coiling.