Mounting the pressure depth sensor – ADS Environmental Services FlowAlert QR 775011 A2 User Manual

Page 46

Advertising
background image

Pressure Depth Sensor and Float Switch Installation 3-23

3/8 – 16 thread tap

Diagonal wire cutters

Folding carpenter’s rule with a brass slide

Rubber stretch tape

Mounting the Pressure Depth Sensor

Two special installation methods are available for mounting the
pressure depth sensor:

¾-band mount

½-band mount

Both mounts require almost identical installation methods. The
only significant differences are that the ¾-band mount allows the
installer to secure the band to both sides of the pipe wall and to
position the pressure depth sensor at the bottom center of the pipe.
These options are not possible using the ½-band mount. Therefore,
the ¾-band mount is the preferable method for mounting the sensor.

However, a ½-band mount may be appropriate for monitoring under
the following circumstances:

Large pipes with deep minimum flows

Large pipes with excessive silt present