Completed telephone cable connected to TELEMETRY/ANTENNA port on

monitor

Wiring the Telephone Cable to the Lightning
Protection Module

Next, wire the telephone cable to the lightning protection module
(ADS p/n 103313) in the following way:

1. Open the front cover of the lighting protection module, and

remove the nuts, washers, and card from the posts inside the
module. Leave only the bottom-most nut on each post.

2. Slice a hole in the grommet in the bottom of the module, and

run the telephone cable up through the grommet into the
module.

3. Place the lugs for the following wires onto the designated posts,

and then re-place a washer and nut onto each post:

 Red wire to Telco network interface

 Top left post (tip)

 Green wire to Telco network interface

 Bottom left post

(ring)

 Blue wire from monitor

 Top right post (tip)