2 show watchdog, 13 diagnostics commands, 1 diagnostics – Kontron AT8402 CLI User Manual

Page 224: 2 copy nvram: diag-report url, 14 pci express commands, 1 set board pcie upstream, 2 show watchdog - 34, 13 diagnostics commands - 34, 14 pci express commands - 34, 1 set board pcie upstream - 34

Advertising
background image

Management Commands

AT8402

AT8402 CLI Reference Manual

Page 5 - 34

Default

disabled (0)

Format

set watchdog bist

<0,60-6000>

set watchdog osloader

<0,120-6000>

set watchdog init

<0,120-6000>

set watchdog application

<0,120-6000>

set watchdog heartbeat

<0,1-6000>

Mode

Privileged EXEC

5.12.2

show watchdog

This command displays the watchdog settings. It displays the values (or string

“disabled”) of different watchdog (during BIST, during loading of kernel and INITRD,

during startup of switching application and during normal execution of switching

application) and the heartbeat of the fpmux application.
Format

show watchdog

Mode

Privileged EXEC

5.13

Diagnostics Commands

5.13.1

diagnostics

This command will start diagnostics. If “interactive” is specified the switch will be

restarted and the diagnostics loaded. The user gets a menu to select interactively a

scenario. A serial console is needed. Otherwise, if a scenario is specified, this scenario

is executed directly. You may start this scenario once or repeated for a time

(timedloop), for a number of repetitions (loop) or forever. The results are stored and

can be displayed by using “show logging diag-report”. Possible scenarios are “full” (all

test purposes except the destructive ones), “quickturn” (scenarios running fast) or

“write” (destructive scenarios).
Format

diagnostics interactive
diagnostics

<scenario>

diagnostics

<scenario>

timedloop

<1-9999999>

diagnostics

<scenario>

loop

<1-9999999>

diagnostics

<scenario>

forever

Mode

Privileged EXEC

5.13.2

copy nvram: diag-report url

This command will copy the tar.gz file containing the results of the last diagnostics run

to a remote TFTP server.
Format

copy nvram:diag-report

<url>

Mode

Privileged EXEC

5.14

PCI express Commands

5.14.1

set board pcie upstream

This command sets the PCI Express port settings for AMC ports and update-channel

port. Only one port must be upstream and only one port must be non-transparent (or

Advertising