2–37

Components and Interfaces

August 2012

Altera Corporation

100G Development Kit, Stratix V GX Edition

Reference Manual

Table 2–30

lists the SFP+ interfaces component reference and manufacturing

information.

CFP Interface

The CFP interface consists of 10 full-duplex transceiver channels. The CFP interface
can support both telecom and datacom applications such as Fibre Channel, Gigabit
Ethernet, ATM, and SONET/SDH.

Table 2–31

lists the pin assignments for the CFP interface and their corresponding

schematic signal names and Stratix V GX pin numbers.

13

SFP3_RDP

1.5-V PCML

C4

Received data (output from the SFP+ interface)

9

SFP3_RS1

2.5-V LVCMOS

AG33

Rate select. Controls the SFP+ interface transmitter.
When input signaling is high, the rate is > 4.25 GBps
and when input signaling is low, the rate

≤ 4.25 GBps.

19

SFP3_TDN

1.5-V PCML

D5

Transmitted data (input to the SFP+ interface)

18

SFP3_TDP

1.5-V PCML

D6

Transmitted data (input to the SFP+ interface)

3

SFP3_TXDISABLE

2.5-V LVCMOS

AH10

Turns off and disables the transmitter laser output

2

SFP3_TXFAULT

2.5-V LVCMOS

AU22

Interface transmitter fault

Table 2–29. SFP+ Interface Pin Assignments, Schematic Signal Names, and Functions (Part 3 of 3)

Board

Reference

(J10)

Schematic Signal

Name

I/O Standard

Stratix V GX

Device Pin

Number

Description

Table 2–30. SFP+ interfaces Component Reference And Manufacturing Information

Board

Reference

Description

Manufacturer

Manufacturing

Part Number

Manufacturer

Website

J10

SFP+ host connector

Samtec

MECT-110-01-M-D-RA1

www.samtec.com

Table 2–31. CFP Interface Pin Assignments, Schematic Signal Names, and Functions (Part 1 of 4)

Board

Reference

(J25)

Schematic Signal

Name

I/O Standard

Stratix V GX

Device Pin

Number

Description

41

CFP_GLB_ALRM

2.5-V LVCMOS

AR9

Global alarm.

0: Alarm on in MDIO alarm register

1: Alarm off

38

CFP_MOD_ABS

2.5-V LVCMOS

AR20

Module absent.

0: Module present. Pull-up resistor on the host

1 or NC: Module absent

37

CFP_MOD_LOPWR

2.5-V LVCMOS

AW37

Module low-power mode.

0: Power-on enabled

1 or NC: Module in low-power (safe) mode

39

CFP_MOD_RST

2.5-V LVCMOS

AH34

Module reset.

0: Reset

1 or NC: Module enabled. Pull-down resistor on
the module